Journeyman Plumber ExamWater Supply SystemsEasy

A plumber is inspecting a residential water heater installation. The water heater is installed in a garage and is equipped with a temperature and pressure (T&P) relief valve. To comply with plumbing codes, the discharge pipe from this T&P valve must terminate in which of the following manners?

  1. AInto the combustion air intake duct of the water heater.
  2. BInto an indirect waste receptor, air gaped, and visible to the occupants.
  3. CInto a sealed drain line that connects directly to the potable water supply.
  4. DDirectly to the exterior of the building, terminating no more than 6 inches above grade.
Show answer & explanation

Correct answer: B. Into an indirect waste receptor, air gaped, and visible to the occupants.

The discharge pipe from a T&P relief valve must terminate to an indirect waste receptor with an air gap, or to the exterior, to prevent contamination of the potable water system and to safely discharge high-temperature, high-pressure water while being visible for inspection.

Why the other options are wrong

  • A. Discharging into a combustion air intake duct is extremely dangerous, posing a risk of fire, explosion, or carbon monoxide poisoning.
  • C. Connecting directly to the potable water supply would create a cross-connection hazard.
  • D. While discharge to the exterior is often allowed, the 'no more than 6 inches above grade' is not universally correct and doesn't specify an air gap or visibility.

T&P Valve Discharge Termination

The safe and code-compliant method for directing the discharge from a water heater's temperature and pressure relief valve.

  • Must prevent cross-connection
  • Must be visible
  • Typically to indirect waste or exterior
  • Requires air gap

Memory trick: T&P discharge: Gap it wide, so no backflow can hide!