Journeyman Plumber ExamWater Supply SystemsHard

A plumber is installing a hot water recirculation system in a large single-family home. The system includes a circulator pump. Which type of check valve is typically recommended for installation on the discharge side of the recirculation pump to prevent reverse flow and ensure efficient operation?

  1. ABall check valve.
  2. BSpring-loaded check valve.
  3. CSwing check valve.
  4. DLift check valve.
Show answer & explanation

Correct answer: B. Spring-loaded check valve.

A spring-loaded check valve is generally preferred on the discharge side of a recirculation pump. Its spring mechanism ensures a positive seal against reverse flow, even with low differential pressure, and helps prevent 'ghost flow' or thermosiphoning when the pump is off, which would defeat the energy-saving purpose of the recirculation system.

Why the other options are wrong

  • A. Ball check valves can be used but may not be as effective as spring-loaded types in preventing low-flow reverse or thermosiphon flow in recirculation systems.
  • C. Swing check valves require a certain amount of flow to close fully and may not prevent low-flow reverse or thermosiphon flow effectively in a recirculation loop.
  • D. Lift check valves are designed for vertical flow and may not seal effectively against low pressures or prevent thermosiphon flow in a horizontal recirculation line.

Recirculation Pump Check Valve

A valve installed on the discharge of a hot water recirculation pump to prevent water from flowing backward through the pump when it is off, ensuring efficient operation and preventing heat loss due to thermosiphoning.

  • Prevents thermosiphoning (ghost flow).
  • Ensures pump efficiency.
  • Spring-loaded types are most effective for positive shut-off.

Memory trick: Recirculation pump: Spring-loaded check, keeps the hot water in check.