EPA Section 608 Universal Certification ExamType II (High-Pressure Appliances)Medium

A technician is performing a major repair on a high-pressure appliance containing 10 pounds of R-407C. After recovering the refrigerant, what is the required evacuation level before recharging the system?

  1. A29.9 inches Hg vacuum
  2. B10 inches Hg vacuum
  3. C0 psig
  4. D15 inches Hg vacuum
Show answer & explanation

Correct answer: B. 10 inches Hg vacuum

For high-pressure appliances with a charge of 10 pounds or less, and after a major repair, the EPA requires evacuation to 10 inches of mercury vacuum. This ensures sufficient removal of non-condensables and moisture.

Why the other options are wrong

  • A. 29.9 inches Hg vacuum is close to a perfect vacuum, typically required for very deep evacuations, but not strictly mandated for this specific scenario.
  • C. 0 psig is atmospheric pressure, not a vacuum level.
  • D. 15 inches Hg vacuum is required for high-pressure appliances with more than 10 lbs of refrigerant, or pre-1992 appliances with less than 10 lbs.

High-Pressure Appliance Evacuation Levels

EPA regulations specify minimum evacuation levels (vacuum) for high-pressure appliances after recovery, which vary based on charge size and type of repair.

  • For major repairs on appliances with >10 lbs, 15 inches Hg vacuum is required.
  • For major repairs on appliances with <=10 lbs, 10 inches Hg vacuum is required.
  • These levels ensure removal of air and moisture, preventing system damage.

Memory trick: After the fix, pull a vacuum, know your pounds, avoid the doom!