CompTIA Server+ (SK0-005)TroubleshootingMedium

A server administrator receives an alert that a server's disk I/O utilization is consistently at 100%, causing applications to be extremely slow and unresponsive. Further investigation reveals that a single logical drive, part of a RAID 5 array, is showing high read/write latency. All other drives in the array appear healthy according to the RAID controller's utility. What is the MOST likely cause of this issue?

  1. AA failing individual disk drive within the RAID 5 array.
  2. BNetwork saturation on the server's NIC.
  3. CInsufficient server RAM for the workload.
  4. DA faulty RAID controller cache module.
Show answer & explanation

Correct answer: A. A failing individual disk drive within the RAID 5 array.

High disk I/O on a single logical drive with high latency on one specific physical drive within a RAID 5 array, while others are healthy, strongly suggests that the individual drive is failing or experiencing severe performance degradation. RAID 5 can tolerate a single drive failure, but a struggling drive can cause significant performance bottlenecks as the controller tries to work around its issues.

Why the other options are wrong

  • B. Network saturation would cause network-related slowdowns and high NIC utilization, not specific high disk I/O and latency on a storage array.
  • C. Insufficient RAM would typically manifest as high CPU utilization (due to excessive swapping) or application crashes, not specifically high disk I/O on a single logical drive with one failing physical disk.
  • D. A faulty RAID controller cache would typically impact all I/O across the array, not just one logical drive or one physical disk's latency.

Degraded RAID 5 Performance

Significant slowdown in a RAID 5 array's read/write operations, often caused by a single failing or degraded drive, even if the array is still functional.

  • RAID 5 can operate with one failed drive, but performance is severely impacted.
  • A 'failing' drive might not be completely dead but struggling, causing high latency and retries.
  • Monitoring individual drive health and I/O statistics is crucial for early detection.

Memory trick: RAID 5: One slow drive makes the whole array a snail!