CompTIA Server+ (SK0-005)TroubleshootingHard

A technician is performing routine maintenance on a server that hosts multiple virtual machines. The server's hardware RAID controller utility reports a 'Predicted Drive Failure' for one of the SAS drives in a RAID 6 array. All other drives are currently healthy, and the array is operating normally. What is the BEST course of action?

  1. AOrder a replacement drive, then replace the predicted failing drive while the server is online (if supported).
  2. BWait for the drive to fail completely before replacing it.
  3. CRebuild the RAID array with the existing drives to clear the error.
  4. DImmediately shut down the server and replace the drive.
Show answer & explanation

Correct answer: A. Order a replacement drive, then replace the predicted failing drive while the server is online (if supported).

A 'Predicted Drive Failure' indicates that SMART data or other internal drive diagnostics predict an imminent failure, but the drive is still functional. RAID 6 can tolerate two drive failures. The best course of action is to proactively replace the predicted failing drive before it actually fails, preventing the array from entering a degraded state and maintaining full redundancy. This can often be done hot-swapping while the server is online, minimizing downtime.

Why the other options are wrong

  • B. Waiting for complete failure increases risk. If another drive fails before the predicted one, the RAID 6 array could become critically degraded or fail entirely.
  • C. Rebuilding the array with an existing predicted failing drive is counterproductive and risky. It puts stress on the potentially failing drive and does not address the underlying hardware issue.
  • D. Shutting down the server unnecessarily disrupts operations when the drive is still predicted to fail, not actually failed. Hot-swapping is preferred if possible.

Predicted Drive Failure (SMART)

A warning from a drive's Self-Monitoring, Analysis, and Reporting Technology (SMART) that indicates an increased likelihood of imminent drive failure, even if the drive is currently functional.

  • Allows for proactive replacement to prevent actual data loss or performance degradation.
  • Commonly reported by hardware RAID controllers or OS utilities.
  • Hot-swapping is often possible for enterprise drives in RAID arrays.
  • Ignoring these warnings significantly increases risk.

Memory trick: Predicted failure? Replace it before the crystal ball shatters!