CompTIA A+ Core 1 (220-1201)Hardware and Network TroubleshootingMedium

A server uses a RAID 5 array of four disks. One disk fails and is hot-swapped with a new drive. Which statement best describes what happens during recovery?

  1. AThe array automatically converts to RAID 0 until manually reconfigured
  2. BThe array continues operating in a degraded state and rebuilds parity data onto the new disk
  3. CThe array is destroyed and must be rebuilt from a full backup
  4. DData is unrecoverable because RAID 5 cannot tolerate any disk failure
Show answer & explanation

Correct answer: B. The array continues operating in a degraded state and rebuilds parity data onto the new disk

RAID 5 uses distributed parity, allowing the array to survive a single disk failure. After replacing the failed disk, the controller rebuilds the missing data using parity information while the array runs in a degraded but functional state.

Why the other options are wrong

  • A. RAID levels do not automatically change type during a rebuild.
  • C. RAID 5 does not require a full restore for a single drive failure since parity allows rebuild.
  • D. RAID 5 specifically tolerates exactly one disk failure using parity.

RAID 5 Fault Tolerance

RAID 5 stripes data with distributed parity across at least three disks, allowing the array to survive and rebuild after a single disk failure.

  • Requires minimum 3 disks
  • Tolerates exactly 1 disk failure
  • Rebuild uses parity data to reconstruct lost disk contents

Memory trick: 'Parity Patches the Puzzle' — one missing piece can be rebuilt.