FAA Aviation Mechanic Airframe (AMA)Airframe Electrical and InstrumentsHard

A technician crimps a new terminal lug onto a wire and inspects the connection before installation. Which inspection finding would require the technician to reject the crimped terminal and remake the connection?

  1. AThe crimp indent is centered on the barrel with no visible strand damage
  2. BSeveral wire strands are visibly cut or broken at the point where they enter the terminal barrel
  3. CThe terminal barrel color-codes correctly for the wire gauge used
  4. DThe wire insulation is visible slightly inside the terminal's insulation grip, with no bare copper exposed beyond the barrel
Show answer & explanation

Correct answer: B. Several wire strands are visibly cut or broken at the point where they enter the terminal barrel

Cut or broken strands at the crimp point significantly reduce the current-carrying capacity and mechanical strength of the termination, creating a high-resistance connection prone to failure; this defect requires the terminal to be cut off and remade with a new, properly sized terminal.

Why the other options are wrong

  • A. A centered, undamaged crimp is a correct, acceptable installation, not a defect.
  • C. Correct color-coding for wire gauge match confirms proper terminal selection, which is acceptable.
  • D. Proper insulation support with no exposed bare copper beyond the barrel is the correct, acceptable condition.

Crimped Terminal Inspection

Visual and mechanical inspection of a crimped wire terminal to verify proper strand condition, indent location, and insulation support before installation.

  • Terminal barrel size must match wire gauge (color-coded)
  • No cut, broken, or missing strands allowed at crimp point
  • No bare copper should extend beyond the terminal barrel

Memory trick: Broken strands = broken connection — cut it off and start over.