FAA Aviation Mechanic Airframe (AMA)Airframe Electrical and InstrumentsEasy

A technician is selecting circuit protection for a new avionics installation. Which characteristic is required of an aircraft circuit breaker but is not necessarily found in a fuse?

  1. AIt must be trip-free so it cannot be held closed against an electrical fault
  2. BIt must open the circuit automatically when current exceeds a rated value
  3. CIt must be reset by replacing it with a new unit after tripping
  4. DIt must be made of a fusible link that melts under overcurrent
Show answer & explanation

Correct answer: A. It must be trip-free so it cannot be held closed against an electrical fault

Aircraft circuit breakers are required to be 'trip-free,' meaning the breaker will open the circuit on an overload even if the operator holds the switch/handle in the closed position. Fuses simply melt open on overcurrent and offer no trip-free holding feature, and unlike fuses they are reset by the crew, not replaced.

Why the other options are wrong

  • B. True of both fuses and breakers, so it doesn't distinguish them.
  • C. Breakers are reset, not replaced; fuses are replaced.
  • D. This describes a fuse, not a breaker.

Trip-Free Circuit Breaker

A circuit breaker designed to open an overloaded circuit automatically regardless of the position of the operating control.

  • Cannot be held closed by the switch during an overload
  • Protects wiring from overheating even if crew tries to override it
  • Required by 14 CFR for most aircraft circuit protection devices

Memory trick: 'Trip-Free' Frees the circuit even if you fight it