CSLB General Building (B)Site Work, Foundations and ConcreteHard

A soils report specifies an allowable bearing capacity of 2,000 pounds per square foot for a site. A contractor designs an isolated column footing measuring 2 feet by 2 feet to support a total column load of 10,000 pounds. Is this footing adequate?

  1. AYes, because the resulting soil pressure of 1,500 psf is below the allowable limit
  2. BNo, because the resulting soil pressure of 2,500 psf exceeds the allowable limit
  3. CNo, because the resulting soil pressure of 5,000 psf far exceeds the allowable limit
  4. DYes, because the resulting soil pressure of 2,000 psf exactly equals the allowable limit
Show answer & explanation

Correct answer: B. No, because the resulting soil pressure of 2,500 psf exceeds the allowable limit

The footing area is 2 ft x 2 ft = 4 square feet. Soil pressure = load / area = 10,000 lb / 4 sq ft = 2,500 psf, which exceeds the allowable bearing capacity of 2,000 psf, so the footing is undersized and must be enlarged.

Why the other options are wrong

  • A. Incorrect pressure calculation; 1,500 psf does not match the given values.
  • C. Incorrect; 5,000 psf misapplies the area calculation.
  • D. Incorrect; the actual calculated pressure exceeds, not equals, 2,000 psf.

Soil Bearing Pressure Check

Verifying that the pressure a footing transmits to the soil (load divided by footing area) does not exceed the allowable bearing capacity from the soils report.

  • Soil pressure = total load ÷ footing area
  • Must be less than or equal to allowable bearing capacity
  • If pressure exceeds capacity, footing must be widened or soil improved

Memory trick: Divide the load by the footprint to see if the soil can take the weight.